Annals of Atoms and Molecules

REVIEW ARTICLE | VOLUME 1 | ISSUE 1 | DOI: 10.36959/961/625 OPEN ACCESS

Carbon Vapor and Carbon Plasma Infrared Emission

László Nemes

  • László Nemes 1*
  • Research Centre for Natural Sciences, Institute of Materials and Environmental Chemistry, Hungary

Nemes L (2017) Carbon Vapor and Carbon Plasma Infrared Emission. Ann Atoms Molecules 1(1):1-5.

Accepted: August 04, 2017 | Published Online: August 07, 2017

Carbon Vapor and Carbon Plasma Infrared Emission

Abstract


A review is given about infrared emission spectroscopy of hot carbon vapors and plasmas obtained using Fourier transform infrared emission and Laser Induced Breakdown Spectroscopy (LIBS) in the mid-infrared range. Laboratory FTIR emission spectra contain vibrational bands from fullerenes C60, C70 whereas laboratory mid-infrared LIBS spectra show bands that belong to mostly unidentified carbon molecules and clusters. Both kinds of spectra are compared to spectral results from infrared astronomy. The spectra are discussed with a view for possible applications in carbon nanostructure research and in infrared astronomy. Extensions for laser induced breakdown (plasma) spectroscopy in the infrared range are suggested.

Keywords


Carbon plasma, Carbon vapor, Infrared emission, FTIR, LIBS, Laser-induced

Abbreviations


LIBS: Laser-Induced Breakdown Spectroscopy; FTIR: Fourier-Transform Infrared Spectroscopy

Introduction


Even before the discovery of fullerenes [1], and their macroscopic production [2], interest arose in finding carbon molecules (e.g. linear carbon chains) in the interstellar medium, in carbon rich stars and in other cosmic sources. Carbon is an abundant chemical element in the Cosmos [3] and is of central importance on Earth from several essential points of view. Thus the discovery of the interesting new allotropes of carbon [1,4] initiated an exponentially growing scientific literature that by now covers a great diversity of chemical and physical disciplines. One interesting subfield is the search for carbon containing molecules in carbon-rich stars [5]. With the developments of infrared facilities on boards of space telescopes and available on ground based infrared observatories detection and identification of carbon molecules became possible.

Identification of large and small carbon molecules is generally straightforward in infrared spectra, especially in the mid-infrared range, as they contain molecular 'fingerprints' used in physical organic and analytical chemistry in molecular structure research. It is obviously important to study the infrared emission spectra of carbon molecules in the laboratory in order to obtain sample spectra to compare to observations, e.g. by astronomical means. Such infrared spectra may be obtained by several techniques. One important method to augment emission studies is to use cryogenic temperature rare gas matrix isolation that provides absorption spectra of isolated solid phase molecules, on the emission side one can generate carbon vapors and study their infrared emission from gas-phase molecules. Another new approach is the application of Laser-Induced Plasma Breakdown Emission Spectroscopy (LIBS) to study carbon plasmas. Plasma spectra are related to the spectra of molecules isolated in the gaseous phase and differ in several aspects from cryogenic matrix spectra, for example in relative band intensities.

The technique of LIBS is widespread in atomic and diatomic spectroscopy as such electronic transitions are mostly observed in the visible and ultraviolet spectral ranges. However conventional LIB spectra of carbon plasmas in these spectral domains do not yield molecular information for C3 and larger carbon molecules. (Although they are usually rich in C2 features, that in turn cannot be observed in vibrational spectra). The electronic transitions of larger carbon molecules are extremely difficult to observe under the usual LIBS conditions.

In recent times a new method has been elaborated for the observation of mid-infrared emission from laser generated plasmas [6-9] that was extended to carbon plasmas [10]. Although application to carbon is still in early developmental stage it has already provided preliminary results that will be discussed in this paper with a view of their applicability for materials science research as well as for infrared astronomy.

Experimental methods

There were several spectroscopic methods reviewed in this paper. Laboratory methods were Fourier-transform infrared emission spectroscopy and laser-induced breakdown spectroscopy in the mid-infrared range. FTIR spectra were taken on the National Solar Observatory Fourier-transform spectrometer at Kitt Peak, Arizona, USA, while mid-infrared LIB spectra at Hampton University, Department of Physics, Hampton, Virginia, USA. Further experimental data are given in sections 1, 2 and 3 below. Infrared astronomical spectra referred to in the text were taken by the Infrared Spectrograph on the NASA Spitzer Space Telescope.

Infrared emission from hot carbon vapors

Gas-phase infrared emission spectra of fullerenes were reported [11,12] and the temperature-dependence of the vibrational bands of C60 and C70 were determined [12]. Solid fullerenes were evaporated in a high temperature furnace and the infrared emission was recorded by a Fourier-transform spectrometer. Together with previous studies of temperature-dependence in solid state spectra of fullerenes [13] and theoretical calculations for infrared and Raman modes [14] enough experimental data have been accumulated for vibrational identification of C60 and C70 in various media and physical states. The C60 molecule has four infrared active (t1u) bands at 1404 (ν25), 1167 (ν26), 570 (ν27) and 528 (ν28) cm-1 (7.1, 8.6, 17.5 and 19 µm, resp.) at about 680 ℃ in the gas phase, whereas C70 has eight infrared active (e1' or a2") bands at 1414 (ν24), 1125 (ν30), 1077 (ν79), 793 (ν33), 639 (ν36), 575 (ν37), 558 (ν35), and 529 (ν82) cm-1 (7.0, 8.9, 9.3, 12.6, 15.6, 17.4, 17.9 and 18.9 µm, resp.) around 700 ℃.

Using the temperature dependence of the vibrational bands of C60 a rough extrapolation to absolute zero temperature was done [12] and the results agreed among these extrapolated values and those observed in argon matrix isolation spectra [15]. Thus data derived from hot vapors may also be useful for the observation of very cold gas-phase fullerenes in astronomical sources. In fact these extrapolated values and matrix isolation data were used for the identification of fullerenes C60 and C70 in planetary nebulae [16,17] using the Infrared Spectrograph on board of the Spitzer Space Telescope [18].

Mid-infrared emission from laser-generated plasmas

Previous studies of time-resolved infrared emission from laser-induced breakdown spectroscopy of inorganic materials [6-9] led to the development of the necessary instrumentation and methodology. This is a significantly new extension of the traditional LIB methods. These studies were and are carried out for remote sensing of chemical, biological and explosive materials, such as various alkali nitrates, ammonium perchlorate and gunpowder [19], and various simple pharmaceuticals such as Tylenol and Aspirin, and compounds like dimethyl phosphate and methyl salycilate [20].

To detect infrared emission in the mid-infrared spectral range the latest instrumentation applied a flash-lamp pumped Q-switched Nd:YAG laser at its fundamental wavelength 1064 nm, and for spectral detection a cooled MCT linear detector array using time-resolved electronics allowing time-gating [19,20]. Linear detector arrays make it possible to run spectra in a few seconds. Previous experiments applied a single element MCT detector and a scanning grating spectrometer, thus were much slower.

Developments of mid-infrared LIBS created the possibility for observing time-resolved infrared emission from laser-generated carbon plasmas. These experiments are somewhat different from analogous remote-sensing studies on energetic materials and pharmaceuticals, as while the ablation laser evaporates or ablates existing molecules from inorganic and organic samples, in the carbon plasma experiments the only readily available molecular entities could only be laser-ablated graphite lattice fragments and macroscopic graphite particles. However many of the signatures observed in carbon plasma infrared emission likely belong to vibrational bands of laser-generated carbon molecules.

Study of carbon plasmas by mid-infrared LIBS

In a recent paper the results of the application of the LIBS technique to study time-resolved infrared emission from carbon plasmas are described in detail [10]. Here the observation of such spectra are summarized and some possible improvements and developments are outlined. The following is a short summary of experimental details, full experimental description is given in [10].

The infrared LIB spectra obtained for carbon were obtained at the Department of Physics, Hampton University, Hampton, Virginia, USA with contributions from Battelle Eastern Sciences and Technology Center, Aberdeen, Maryland, USA. The spectra were run between 7.5 and 11.5 µm, and in one case between 4.5 and 11.5 µm. A grating spectrometer of 150 cm focal length was used, providing about 80 nm spectral resolution. Detection was made by a cooled HgCdTe (MCT) detector at 77 K. The spectral sensitivity of the detector was at maximum at 10 micron, near 40% at 4 micron, and near 70% at 12 micron. Infrared radiation from target plasma was focused by ZnSe optics onto the 2 mm wide entrance slit of the spectrometer. Time resolution made it possible to use spectral delays 10-20 microsecond relative to the laser pulse. Scattered laser light and higher-order spectra were cut using low-pass filters at 4 and 7.4 micron, total spectral taking time was near 1 hour. The spectrometer was encased in a plastic box that was flushed by ultra pure grade N2, Ar or He at atmospheric pressure.

The infrared spectra contained broad emission bands. All spectra were characterized by strong continuous backgrounds. Spectra recorded in the 8 - 11.5 µm interval were weaker than those in the 4.5 - 8 µm region. The broadness of the emission bands is due to a lesser extent to the limited spectral resolution (about 80 nm) but mainly to the high target and plasma temperature, the fundamental source for their width is however their molecular origin. At plasma temperatures vibrational and rotational excitations are extensive leading to broad spectral envelopes. Atomic lines would have been much narrower. In addition in the infrared region studied no neutral and/or ionic atomic lines are expected to appear with significant intensity [21].

The observed infrared emission did not show the room temperature blackbody emission expected from the spectrometer body itself, and significant bands were only observed in atmospheric pressure rare gases. In ref. [10] it was found that emission spectra were somewhat different in argon and in helium. Figure 1 below shows a comparison in the range 7.4-11.5 µm. The spectra shown were background corrected and denoised using methods described in [10] (Figure 1).

This difference suggests molecule and cluster formation in the plasma. However not all spectral features may be due to molecule formation in the plasma, as the laser ablates graphene fragments from the graphite target. In addition macroscopic graphite particles may be ablated or could form within the plasma. Graphene fragments are Dehydrogenated PAH (dPAH) molecules, ie condensed aromatic carbon rings. Infrared bands of dPAH molecules computed using high level density functional methods were reported in the literature [22]. The strongest infrared bands computed for dPAH molecules lie between 5 and 12 µm and between 17 and 28 µm. dPAH molecules are essentially nano-graphene particles, and in a theoretical vibrational study they were found to possess complicated vibrational phonon modes in the mid-infrared region, as calculated by atomistic methods using a modified Brenner potential [23]. For example, nano-graphene molecules with 53 carbon atoms have high phonon densities between 200 and 2000 cm-1 (50-5 µm). Perfectly regular graphene with 1600 atoms has a well isolated strong phonon density peak at around 5.9 µm [24].

In addition the strong band observed between 4.4 and 5.4 µm does likely contain vibrational features of C3, C5, C6, C7 and C9 linear carbon chain molecules, as expected from their matrix isolation infrared spectra [25].

An interesting possibility is that graphite target laser ablation plasmas contain the fullerenes C60 and C70. The availability of laboratory hot carbon vapor infrared spectra and infrared astronomical observations provide comparisons. Such a comparison is shown in (Figure 2).

In the above Figure black denotes mid-infrared LIB spectra [10], magenta denotes the spectrum from the Spitzer telescope [18] (the author acknowledges Professor Jan Cami for sending the digital form of the spectrum), while red denotes infrared spectra from hot C60 vapor [12]. As shown the ν25 and ν26 infrared modes of C60 at around 7 and 8.5 micron overlap between the laboratory C60 vapor and the Spitzer infrared spectra, but the mid-infrared LIB spectra do not have prominent bands at these wavelengths (see the boxes in the figure bracketing the two fundamental modes of C60). The infrared modes of C70 also fall in the wavelength range of (Figure 2). The mid-infrared LIB spectra however contain strong emission bands at around 4.7, 6 and 7.4 microns. None of these correspond to C60 or C70 infrared bands, or those of linear carbon clusters. The 7.4 micron band might contain the infrared signatures of dPAH molecules (nano-graphenes).

Discussion and Propositions


Infrared emission spectra observed by the Mid-Infrared LIBS (MIRLIBS) method are at present difficult to assign with any certainty to known carbon molecules. As mentioned before, there are only two groups of molecules (linear carbon chains and Dehydrogenated PAHs) for which previously obtained experimental data and high-level theoretical calculations provide a tentative basis for identification. Fullerenes C60 and C70 could not yet been positively identified in MIRLIB spectra and there are strong emission bands for which at present no molecular assignments could be given.

The present results from mid-infrared LIB spectra of carbon plasmas [10] are thus only preliminary as the experiments were performed using an equipment designed for observing inorganic and organic molecular matter for remote-sensing analytical applications under atmospheric conditions.

In order to exploit this new analytical technique the method should be extended and refined. Relative to the published spectra [10] obtained with a single element MCT (HgCdTe) detector/scanning spectrometer requiring up to 1 hour of recording 10 spectra, the newly developed linear array MCT detector/grating based monochromator should provide fast acquisition of the infrared spectra (only 5 sec is needed to average 4 single-shot plasma spectra [19]). Thus with the linear array detector many spectra can be averaged resulting in significantly improved signal to noise ratio.

Another aspect is the time-resolved ability of the experimental arrangement. While in the previous experiments [10] time-delays up to 20 microseconds after the laser-pulse were used, in the experiments with the linear array time resolution was extended to 1 ms delay. This is important e.g. for observing fullerenes as their formation in the plasma requires time scales longer than 10-20 microseconds. In addition one would need warm background gases for cluster formation compared to the room temperature surrounding gas in previous experiments [10].

Increase of spectral resolution greater than 80 nm in further experiments would bring obvious advantages. An important extension of MIRLIB spectra of carbon and other substances would be the variation of environmental gas pressure. For remote-sensing applications that often are carried out in ambient air, the necessity of using atmospheric ( about 100 kPa) pressure is obvious, however to study the formation of atomic clusters much lower pressures are usually needed (maybe down to a few tens of Pascal).

MIRLIB spectra are dominated by a strong thermal (blackbody) background. Using ablation lasers with sub-nm pulse lengths (femtoseconds?) that have much less thermal contribution than nanosecond lasers, this thermal background could be reduced. Such fast lasers may also make it possible to separate the infrared emission from surface molecules from thermal emission from excitation of laser generated clusters.

A significant advance of MIRLIB spectroscopy could result from simultaneous use of the conventional LIBS technique (in the visible and ultraviolet region) and the MIRLIBS method. These two methods are quasi mutually exclusive. As in the infrared range atomic lines of various ionization stages are not observed, whereas in conventional LIBS atomic lines are easily used to obtain electron temperature and electron volume density values (based on relative intensities and line widths of atomic lines), quantitative characterization of the plasmas in combined LIBS spectral ranges would be possible. The present state of developments infrared LIB spectroscopy and relevant technical aspects are reviewed in a recent paper [26].

With increased spectral resolution, better signal to noise ratios, non-thermal lasers and available plasma electron parameters it might be possible to study vibrational excitation conditions, further molecular identifications and maybe derive molecular formation mechanisms (thus plasma chemistry) as well.

Developments in the experimental techniques could provide important help for understanding carbon cluster formation which is a central theme in producing various carbon nanostructures. In addition the MIRLIBS technique could be extended to other cluster forming chemical elements, such as metals, alkali metals, semi-metals and some non-metallic elements (such as sulphur), thus a large part of the periodic table. As these atomic clusters usually emit in the far infrared range MIRLIBS wavelengths should be extended. This depends on the evolution of fast far-infrared detectors. Such studies may also lead to practical results for the nanomaterials field.

Infrared astronomy may also benefit from carbon MIRLIB spectroscopy in identifying the molecular origin and physical state of cosmic infrared emitting sources containing carbon, along the line of the Spitzer spectra of fullerenes [16,17]. In particular with the mid-infrared observational possibilities of the coming James Webb Space Telescope between 5 and 28 microns [27] one may expect extensions of the Spitzer telescope's spectroscopic studies.

Thus it appears to the present author that infrared emission spectroscopy of carbon and other plasmas has interesting future.

References


  1. Kroto HW, Heath JR , O'Brien SC, et al. (1985) C60: Buckminster fullerene. Nature 318: 162-163.
  2. Kraetschmer W, Lamb LD, Fostiropoulos K, et al. (1990) Solid C60: a new form of carbon. Nature 347: 354-358.
  3. Salama THF (1998) Carbon in the Universe. Science 282: 2204-2210.
  4. https://en.wikipedia.org/wiki/Allotropes_of_carbon.
  5. Groenewegen MAT (1998) Infrared Emission of Carbon Stars. Astrophysics and Space Science Library 230: 73-86.
  6. Yang CS, Brown E, Hommerich U, et al. (2008) Mid-infrared Laser-Induced Breakdown Spectroscopy Emission from Alkali Metal Halides. Applied Spectroscopy 62: 714-716.
  7. Oyebola O, Hommerich U, Brown E, et al. (2011) Concentration dependent studies on the Laser-Induced Mid-infrared Emission from KCl-NaCl Tablets. Photonic Lett Poland 3: 171-174.
  8. Yang CS, Brown E, Hommerich U, et al. (2012) Long-wave, infrared Laser-induced Breakdown (LIBS) Spectroscopy Emissions from Energetic Materials. Applied Spectroscopy 66: 1397-1402.
  9. Yang CS, Brown E, Kum-Barimah E, et al. (2014) Mid-infrared, long wave infrared (4-12 µm) molecular emission signatures from pharmaceuticals using laser-induced breakdown spectroscopy (LIBS). Applied Spectroscopy 68: 226-231.
  10. Nemes L, Brown E, Yang CS, et al. (2017) Mid-infrared emission spectroscopy of carbon plasma. Spectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy 170: 145-149.
  11. Frum CI, Engleman R Jr, Hedderich HG, et al. (1991) The Infrared Emission spectrum of gas-phase C60 (Buckminster fullerene). Chemical Physics Letters 176: 504-508.
  12. Nemes L, Ram RS, Bernath PF, et al. (1994) Gas-phase infrared emission spectra of C60 and C70: Temperature dependent studies. Chemical Physics Letters 218: 295-303.
  13. Chase B, Herron N, Holler E (1992) Vibrational spectroscopy of fullerenes (C60 and C70). Temperature dependant studies. J Phys Chem 96: 4262-4266.
  14. Dresselhaus MS, Dresselhaus G, Eklund PC (1995) Science of Fullerenes and Carbon Nanotubes, Their Properties and Applications. (1st edn), Academic Press, New York.
  15. Haufler RE, Conceicao J, Chibante LPF, et al. (1990) Efficient production of C60 (buckminster fullerene), C60H36, and the solvated buckide ion. J Phys Chem 94: 8634-8686.
  16. Cami J, Bernard-Salas J, Peeters E, et al. (2010) Detection of C60 and C70 in a young planetary nebula. Science 329: 1180-1182.
  17. Garcia-Hernandez DA, Manchado A, Garcia-Lario P, et al. (2010) Formation of fullerenes in H-containing planetary nebulae. The Astrophysical Journal Letters 724: 39-43.
  18. home.strw.leidenuniv.nl/~brandl/IRS_spectrograph.pdf.
  19. Yang CS, Jin F, Trivedi S, et al. (2016) Time-resolved long-wave infrared laser-induced breakdown spectroscopy of inorganic energetic materials by a rapid mercury-cadmium-telluride linear array detection system. Appl Opt 55: 9166-9172.
  20. Yang CS, Brown E, Kumi-Barimah E, et al. (2015) Rapid long-wave infrared laser-induced breakdown spectroscopy measurements using a mercury-cadmium-telluride linear array detection system. Applied Optics 54: 9695-9702.
  21. Kramida A, Ralchenko Y, Reader J (2014) NIST ASD Team, NIST Atomic Spectra Database (version 5.2).
  22. Mackie CJ, Peeters E, Bauschlicher CW Jr, et al. (2015) Characterizing the infrared spectra of small, neutral, Fully Dehydrogenated Polycyclic Aromatic Hydrocarbons. The Astrophysical Journal 799: 1-11.
  23. Kumar SK, Peeters FM (2013) Vibrational Properties of nanographene. Nanoscale Systems 2: 10-29.
  24. Vandescuren M, Hermet P, Meunier V, et al. (2008) Theoretical study of the vibrational edge modes in graphene nanoribbons. Phys Rev B 78: 195401.
  25. Strelnikov D, Reusch R, Kraetschmer W (2005) Assignment of carbon containing molecules in cryogenic matrices by selective laser-induced oxidation. J Phys Chem 109: 7708-7713.
  26. Chaffee CD (2017) LIBS continues to evolve. Optics and Photonics News.
  27. https://www.jwst.nasa.gov/.

Abstract


A review is given about infrared emission spectroscopy of hot carbon vapors and plasmas obtained using Fourier transform infrared emission and Laser Induced Breakdown Spectroscopy (LIBS) in the mid-infrared range. Laboratory FTIR emission spectra contain vibrational bands from fullerenes C60, C70 whereas laboratory mid-infrared LIBS spectra show bands that belong to mostly unidentified carbon molecules and clusters. Both kinds of spectra are compared to spectral results from infrared astronomy. The spectra are discussed with a view for possible applications in carbon nanostructure research and in infrared astronomy. Extensions for laser induced breakdown (plasma) spectroscopy in the infrared range are suggested.

References

  1. Kroto HW, Heath JR , O'Brien SC, et al. (1985) C60: Buckminster fullerene. Nature 318: 162-163.
  2. Kraetschmer W, Lamb LD, Fostiropoulos K, et al. (1990) Solid C60: a new form of carbon. Nature 347: 354-358.
  3. Salama THF (1998) Carbon in the Universe. Science 282: 2204-2210.
  4. https://en.wikipedia.org/wiki/Allotropes_of_carbon.
  5. Groenewegen MAT (1998) Infrared Emission of Carbon Stars. Astrophysics and Space Science Library 230: 73-86.
  6. Yang CS, Brown E, Hommerich U, et al. (2008) Mid-infrared Laser-Induced Breakdown Spectroscopy Emission from Alkali Metal Halides. Applied Spectroscopy 62: 714-716.
  7. Oyebola O, Hommerich U, Brown E, et al. (2011) Concentration dependent studies on the Laser-Induced Mid-infrared Emission from KCl-NaCl Tablets. Photonic Lett Poland 3: 171-174.
  8. Yang CS, Brown E, Hommerich U, et al. (2012) Long-wave, infrared Laser-induced Breakdown (LIBS) Spectroscopy Emissions from Energetic Materials. Applied Spectroscopy 66: 1397-1402.
  9. Yang CS, Brown E, Kum-Barimah E, et al. (2014) Mid-infrared, long wave infrared (4-12 µm) molecular emission signatures from pharmaceuticals using laser-induced breakdown spectroscopy (LIBS). Applied Spectroscopy 68: 226-231.
  10. Nemes L, Brown E, Yang CS, et al. (2017) Mid-infrared emission spectroscopy of carbon plasma. Spectrochimica Acta - Part A: Molecular and Biomolecular Spectroscopy 170: 145-149.
  11. Frum CI, Engleman R Jr, Hedderich HG, et al. (1991) The Infrared Emission spectrum of gas-phase C60 (Buckminster fullerene). Chemical Physics Letters 176: 504-508.
  12. Nemes L, Ram RS, Bernath PF, et al. (1994) Gas-phase infrared emission spectra of C60 and C70: Temperature dependent studies. Chemical Physics Letters 218: 295-303.
  13. Chase B, Herron N, Holler E (1992) Vibrational spectroscopy of fullerenes (C60 and C70). Temperature dependant studies. J Phys Chem 96: 4262-4266.
  14. Dresselhaus MS, Dresselhaus G, Eklund PC (1995) Science of Fullerenes and Carbon Nanotubes, Their Properties and Applications. (1st edn), Academic Press, New York.
  15. Haufler RE, Conceicao J, Chibante LPF, et al. (1990) Efficient production of C60 (buckminster fullerene), C60H36, and the solvated buckide ion. J Phys Chem 94: 8634-8686.
  16. Cami J, Bernard-Salas J, Peeters E, et al. (2010) Detection of C60 and C70 in a young planetary nebula. Science 329: 1180-1182.
  17. Garcia-Hernandez DA, Manchado A, Garcia-Lario P, et al. (2010) Formation of fullerenes in H-containing planetary nebulae. The Astrophysical Journal Letters 724: 39-43.
  18. home.strw.leidenuniv.nl/~brandl/IRS_spectrograph.pdf.
  19. Yang CS, Jin F, Trivedi S, et al. (2016) Time-resolved long-wave infrared laser-induced breakdown spectroscopy of inorganic energetic materials by a rapid mercury-cadmium-telluride linear array detection system. Appl Opt 55: 9166-9172.
  20. Yang CS, Brown E, Kumi-Barimah E, et al. (2015) Rapid long-wave infrared laser-induced breakdown spectroscopy measurements using a mercury-cadmium-telluride linear array detection system. Applied Optics 54: 9695-9702.
  21. Kramida A, Ralchenko Y, Reader J (2014) NIST ASD Team, NIST Atomic Spectra Database (version 5.2).
  22. Mackie CJ, Peeters E, Bauschlicher CW Jr, et al. (2015) Characterizing the infrared spectra of small, neutral, Fully Dehydrogenated Polycyclic Aromatic Hydrocarbons. The Astrophysical Journal 799: 1-11.
  23. Kumar SK, Peeters FM (2013) Vibrational Properties of nanographene. Nanoscale Systems 2: 10-29.
  24. Vandescuren M, Hermet P, Meunier V, et al. (2008) Theoretical study of the vibrational edge modes in graphene nanoribbons. Phys Rev B 78: 195401.
  25. Strelnikov D, Reusch R, Kraetschmer W (2005) Assignment of carbon containing molecules in cryogenic matrices by selective laser-induced oxidation. J Phys Chem 109: 7708-7713.
  26. Chaffee CD (2017) LIBS continues to evolve. Optics and Photonics News.
  27. https://www.jwst.nasa.gov/.