Spectrum-Averaged Neutron Fluence-to-Dose Conversion Coefficients of 252Cf, 252Cf/D2O, 241AmB, 241AmBe and 239PuBe Neutron Sources, Using the New Dosimetric Quantities of ICRP/ICRU
Abstract
The spectrum-averaged neutron fluence-to-ambient dose conversion coefficient for 252Cf, 252Cf/D2O, 241AmB, 241AmBe and 239PuBe neutron sources were calculated using the neutron fluence-to-dose conversion coefficients for the personal dose and the ambient dose which are the new dosimetric quantities, defined in the ICRP/ICRU joint report. One of the goals of defining these new dosimetric quantities is to harmonize the operational quantities with the protection quantities. By using Monte Carlo methods the spectra of the neutron sources and the total fluences were estimated, with the spectra and the neutron fluence-to- dose conversion coefficients the ambient and the personal dose were estimated. These values where normalized to the total neutron fluence to obtain the spectrum-averaged neutron fluence-to-dose conversion coefficients that were compared with those obtained for the H*(10), Hp,s(10,0°) and EAP using the coefficients from the ICRP 74 and the ICRP 116. For 10-9 to 20 MeV neutrons, the new dosimetric quantities the operational and the protection quantities are harmonized.
Keywords
Neutron, Dose conversion coefficient, Personal dose, Ambient dose
Introduction
Living beings are exposed to ionizing radiation fields of natural and artificial origin. The uses and applications of ionizing radiation are very diverse and contribute to the well-being of the population. However, improper use of artificial radiation sources leads to unnecessary exposure, posing a risk to the exposed person.
The effects of exposure to ionizing radiation include reactions in the different tissues of the human body, known as Deterministic and Stochastic effects respectively. Stochastic effects include hereditary effects and the risk of inducing cancer. In the aim to reduce the risk of stochastic effects and to prevent the deterministic effects, the radiation protection defines limit annual doses evaluated by monitoring programs and supervised by radiation protection legislation [1].
The organ absorbed dose, equivalent dose and effective dose are protection quantities defined by the International Commission on Radiological Protection (ICRP) to act as optimization guidelines and to define dose limits for radiation workers and members of the public [2]. Protection dosimetric quantities are not-point quantities because are determined using anthropometric phantoms in order to determine the absorbed doses by organs and body tissues considering radiation weighting factors. On the other hand, protection quantities are not measurable, and the International Commission on Radiation Units and Measurements (ICRU) defined the ambient dose equivalent and the directional dose equivalent as operational quantities [3,4], which are measurable, whose values estimates the protection quantities [5]. Is worth to note that the operational dosimetric quantities are defined for external and internal exposure; for external exposure, operational quantities are used for the calibration of instruments and personal dosimeters [6].
External dose coefficients, traditionally known as fluence-to-dose conversion coefficients, are the link between the operational and protection quantities and the dosimetric and radiometric quantities, as is shown in equation (1) [7,8].
Here, R is the desired dosimetric quantity; the function represents the dosimetric quantity contribution, at point in the target, due to a particle with energy Es travelling in the direction per differential unit of path. The function is the particle fluence (known as energy-and-angular fluence). In this equation, the target could be an area monitor, dosimeter, the human body, etc.
For external exposure, the desired dose at point (Δ( )) is calculated using the fluence-to-dose conversion coefficients (δ (E)) and the equation (1) becomes equation (2).
In this equation, is the amount of particles at a point allocated in with energy between E and E + dE, (from the lowest Em energy to the largest EM energy), also known as the particle spectrum.
Compared with another ways of producing neutrons, isotopic neutron sources, are inexpensive, small and easy to work with, their disadvantages includes the low neutron yield and that produce γ-rays. These sources includes those based on (α, n) and (γ, n) reactions and those that produce neutrons due to spontaneous fission [9].
Due to their neutron spectra and dosimetric features Bare 252Cf, D2O-moderated 252Cf (252Cf/D2O), 241AmBe and 241AmB are widely used for the calibration of neutron area monitors and neutron dosimeters [10-12], as well as 239PuBe [13,14]. In this endeavor, the knowledge of fluence-to-dose conversion coefficients and the neutron spectra are important to determine the dose [15,16]. The spectrum-averaged neutron fluence-to-dose conversion coefficient (δφ) characterize any neutron source used for calibration. The δφ is the dose per unit of neutron flux, and it is calculated as is shown in equation 3.
In 1971 was published the first set of neutron fluence-to dose conversion coefficients by the National Council on Radiation Protection and Measurements. In both cases, was estimated the maximum absorbed dose equivalent in two phantoms: A 30 cm-thick semi-infinite slab and 30 Ø × 60 cm cylinder. Since then, other reports have come to light including updated sets of fluence-to-dose conversion coefficients for different dosimetric quantities, different phantoms and other particles. Recently, in a ICRP/ICRU joint report are included changes in the concept of operational quantities, particularly for individual and area monitoring where the two new dosimetric quantities are defined and the neutron fluence-to-dose conversion coefficients are calculated using the same anthropomorphic phantoms used in the calculation of neutron fluence-to-dose conversion coefficient for protection quantities [17].
In the ICRU report 95, the neutron fluence-to-dose conversion coefficients for operational quantities were calculated using the same phantoms as the protection coefficients; thus, operational quantities are now closely related to dosimetric protection quantities. In addition, is defined a new operational quantity: The ambient dose (H*) and the personal dose (Hp). For H* the conversion coefficients (h*(E)) relates the neutron spectrum with the maximum value of the effective dose (Emax) among all irradiation conditions; for Hp, the conversion coefficients (hp (E)) relates the neutron spectrum to the effective dose (E) [17]. Therefore, is important to calculate the value of the new dosimetric quantities per unit neutron fluence for the neutron sources that are widely used to calibrate the neutron area monitors and the dosimeters used for individual dosimetry.
The objective of this work was to calculate the spectrum-averaged neutron fluence-to-dose conversion coefficient of bare 252Cf, 252Cf/D2O, 241AmB, 241AmBe and 239PuBe neutron sources for the new dosimetric quantities: Ambient dose and personal dose recommended in ICRP/ICRU joint report 95 [17]; and to compare with the spectrum-averaged neutron fluence-to-dose conversion coefficients using the neutron fluence-to-dose conversion coefficients for H*(10), Hp,s(10,0°) from the ICRP publication 74 [18] and the EAP from the ICRP publication 116 [19]. In addition, to evaluate the use of different spectra as source-term for the 241AmBe neutron source.
Materials and Methods
With the Monte Carlo code, MCNP5 [20] was built a model having a point-like neutron source and a point-like detector in vacuum. The source-to-detector distance was 100 cm. The source term were the neutron spectra, Φ(E) of bare 252Cf, 252Cf/D2O, 241AmB, 241AmBe and 239PuBe neutron sources [14,15]. For the 241AmBe source calculations were also carried out using as source term the spectrum from ISO [12].
With tally F5 the neutron spectrum (Φ(E)) and the total neutron fluence (Ø) in the detector were estimated. The spectrum was multiplied by the neutron fluence-to-ambient dose and personal dose (h*(E), hp (E)) conversion coefficients from the ICRU report 95, and integrated in energy [17].
The spectrum-averaged neutron fluence-to-ambient dose conversion coefficient for each neutron source was calculated using equation 4, and the spectrum-averaged neutron fluence-to-personal dose conversion coefficient was calculated using equation 5.
For each source 108 histories were used obtaining uncertainties from 0 to 0.02%. For comparison with the new dosimetric quantities, the same calculations were carried out using the neutron fluence-to-dose conversion factors from the ICRP publication 74 [18] and the ICRP publication 116 [19].
Results and Discussion
In Figure 1 are the neutron fluence-to-dose conversion coefficients for the new ICRU dosimetric quantities, hp (E) and h*(E). In addition, are included the dose coefficients for the ambient dose equivalent (h*(10) (E)), and the effective dose equivalent for anterior-posterior exposure (eAP(E)).
From 10-9 to 50 MeV dose coefficients of operational quantities hp (E, 0°) and h*(E) are equal than the protection quantity eAP(E), for larger energies the h*(E) is larger, while hp(E,0°) remains the same as eAP(E). The goal of the new operational quantities of matching the protection quantities is satisfied.
In Table 1, is the spectrum-averaged neutron fluence-to-dose conversion coefficient for the effective dose for antero-posterior exposure (eAP), the ambient dose equivalent (h*(10)), and the personal dose equivalent (hp,s(10, 0°))using the ICRP 74 [18] neutron fluence-to-dose conversion coefficients, for the neutron sources.
Both operational values (h*(10) and hp,s(10,0°)) are different from the protection values, and corrections are required during the calibration of personal dosimeters and neutron area monitors. The spectrum-averaged neutron fluence-to-ambient dose conversion coefficient varies as the neutron mean energy changes.
As source term were used the neutron spectra from the International Atomic Energy Agency [13,14]. Also, the ISO [12] 241AmBe spectrum was used as source term. The neutron spectrum used as source term impact in the spectrum-averaged neutron fluence-to dose conversion coefficients. Using the ISO spectrum the coefficients are 5.10, 0.26, and 0.98% larger in comparison with coefficients calculated with the neutron spectra published by the IAEA.
In Table 2 is the spectrum-averaged neutron fluence-to-dose conversion coefficient for the effective dose for antero-posterior exposure (eAP), the personal dose (hp (0°)), and the ambient dose (h*) using the ICRU Report 95 [17] neutron fluence-to-dose conversion coefficients, for the neutron sources.
For both new operational quantities, the spectrum-averaged neutron fluence-to-dose conversion coefficient, for the personal dose (hp (0°) and the ambient dose (h*) are equal to the effective dose for antero-posterior exposure (eAP), which is a protection quantity: Fulfilling, the objective of the ICRP/ICRU joint report [17]. Due to this, the neutron fluence-to-dose conversion coefficients of the three dosimetric quantities are the same for 10-9 to 50 MeV neutrons (Figure 1).
For the three quantities, the δφ, using as source-term, the 241AmBe spectrum from the ISO [12] is 4.4% larger in comparison of using the spectra from the IAEA [13,14]. For h* obtained with the ISO spectrum is the same reported by [21] using the ICRP/ICRU joint report draft.
Conclusions
In this work was calculated the spectrum-averaged neutron fluence-to-dose conversion coefficient of bare 252Cf, 252Cf/D2O, 241AmB, 241AmBe and 239PuBe neutron sources for Ambient dose and personal dose, which are new dosimetric quantities recommended by ICRP/ICRU joint report 95. These values, were compared with the spectrum-averaged neutron fluence-to-dose conversion coefficients using the neutron dose coefficients for H*(10), Hp,s(10,0°) from the ICRP publication 74 and the EAP from the ICRP publication 116. For the 241AmBe source was evaluated the effect of using different spectra as source-term.
The use of the new dosimetric quantities for 10-9 to 20 MeV improves the coherence between operational and protection quantities.
The spectrum-averaged neutron fluence-to-dose conversion coefficients (δφ) of bare 252Cf, 252Cf/D2O, 241AmB, 241AmBe, and 239PuBe neutron sources are larger than the δφ obtained with the dose coefficients from the ICRP 74 and ICRP 116, because the new dosimetric quantities are based in different paradigm.
Regardless the dose coefficients, the use of different neutron spectrum, as source-term, for 241AmBe, produces different δφ, being larger when the ISO spectrum is used in comparison of using the IAEA neutron spectra.
Acknowledgments
The second author (MGGR) thanks to CONACyT (Mexico) for the scholarship granted to pursue the postgraduate degree.
References
- Petoussi-Henss N, Bolch WE, Eckerman KF, et al. (2014) ICRP Publication 116 - the first ICRP/ICRU application of the male and female adult reference computational phantoms. Phys Med Biol 59: 5209-5224.
- Endo A (2016) On behalf of ICRU report committee 26 on operational radiation protection quantities for external radiation. Operational quantities and new approach by ICRU. Ann ICRP 45: 178-187.
- ICRU (1985) Determination of dose equivalents resulting from externalradiation sources. International Commission on Radiation Units and Measurements. 10.
- ICRU (1988) Determination of dose equivalents from external radiation sources-Part 2. International Commission on Radiation Units and Measurements. 51.
- Masilela TAM, Delorme R, Prezado Y (2021) Dosimetry and radioprotection evaluations of very high energy electron beams. Scientific Reports 11: 20184.
- Veinot KG (2019) Fundamental concepts and quantities. Chapter 2 published in: Dewji SA, Hertel NE (1st edn), Advanced Radiation Protection Dosimetry. Boca Raton, FL. CRC Press. 68.
- Hertel NE, Jokisch D (2019) Dose coefficients. Chapter 8 published in: Dewji SA, Hertel NE, (1st edn), Advanced Radiation Protection Dosimetry. Boca Raton, FL. CRC Press. 506.
- Shultis JK, Faw RE (2000) Radiation shielding. La Grange Park, IL. American Nuclear Society.
- Vega-Carrillo HR, Martinez-Ovalle SA (2016) Few groups neutron spectra, and dosimetric features, of isotopic neutron sources. Applied Radiation and Isotopes 117: 42-50.
- ISO (2000) Reference neutron radiations-part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field. Internal. ISO 8529-2.
- ISO (2001) Reference neutron radiation-part 1: Characteristics and methods of production. International Standard Organization ISO 8529-1.
- ISO (2001) Reference neutron radiations-part 3: Calibration of area and personal dosimeters and determination of response as a function of energy and angle of incidence. International Standard Organization ISO 8529-3.
- IAEA (2001) Compendium of neutron spectra and detector responses for radiation protection purposes. Supplement of technical reports series No. 318. International atomic energy agency. Technical report series No. 403. Vienna.
- IAEA (1990) Compendium of neutron spectra and detector responses for radiation protection purposes. International atomic energy agency. Technical report series No. 318. Vienna.
- Thomas D, Bedogni R, Méndez R, et al. (2018) Revision of ISO 8529 - Reference neutron radiations. Radiation Protection Dosimetry 180: 21-24.
- Vega-Carrillo HR, Manzanares-Acuña E, Iñiguez MP, et al. (2007) Spectrum of isotopic neutron sources inside concrete wall spherical cavities. Radiation Measurements 42: 1373-1379.
- ICRU (2020) Operational quantities for external radiation exposure. International Commission on Radiation Units and Measurements ICRU Report 95. Journal of the ICRU 20.
- ICRP (1996) Conversion coefficients for use in radiological protection against external radiation. ICRP Publication 74. Annals of the ICRP 26.
- ICRP (2010) Conversion coefficients for radiological protection quantities for external radiation. ICRP Publication 116. Annals of the ICRP 40.
- X-5 Monte Carlo Team (2003) MCNP - A general Monte Carlo N-particle Transport Code, Version 5. LA-UR-03-1987. Los Alamos National Laboratory.
- Pozzi F, Ferrarini M, Ferrulli F, et al. (2019) Impact of the newly proposed ICRU/ICRP quantities on neutron calibration fields and extended range neutron rem-counters. J Radiol Prot 39: 920-937.
Corresponding Author
Hector Rene VEGA-CARRILLO, UaEN-UAZ C. Cipres 10 Fracc. La Penuela 98060 Zacatecas, Zac, Mexico
Copyright
© 2023 Vega-Carrillo HR, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.