Table 2b: Differences found in lung function during the evolution.
Patients | Differences in FEV1 ml/ppd and FVC ml/ppd at the atelectasis diagnosis (0 months) vs. 6, 12 and 24 months and the last collected | |||
FEV1 (6-0) FVC (0-6) |
FEV1 (12-0) FVC (12-0) |
FEV1 (24-0) FVC (24-0) |
FEV1 (last-0) FVC (last-0) |
|
1 |
-590/-14 -530/-14 |
-230/-6 -140/-3 |
-1570/-35 -2280/-43 |
|
2 |
0/0 20/1 |
-140/-4 -40/0 |
-930/-26 -1030/-25 |
|
3 |
420/10.5 -330/-11 |
510/13.3 -130/-5.4 |
600/16.1 50/0.54 |
600/16.1 50/0.54 |
4 |
-70/-1 200/7 |
160/5 840/19 |
-750/-32 -1900/53 |
|
5 |
-1100/-32 -1200/-34 |
|||
6 |
140/4 610/13 |
190/5 840/19 |
-10/0 0/1.5 |
-280/-7 -140/-1 |
7 |
-560/-20 -580/-17 |
-410/-14 -280/-8 |
-750/-25 -1200/-37 |
-750/-25 -1200/-37 |
8 |
-230/-6 -80/? |
-225/-6 -50/? |
-90/-2 -20/? |
-180/-3 -20/? |
9 |
40/1.7 400/12.3 |
10/0.8 400/12.3 |
1990/55.5 (post-Tx) 1480/29.5 |
|
10 |
-180/-4.9 -330/-8 |
2310/35.1 (post-Tx) 1300/26.3 |
2150/51.2 1560/31.9 |
|
11 |
-250/-10 -190/-10 |
1790/57 (post-Tx) 1550/36 |
1790/57 1150/36 |
FEV1: Forced expiratory volumen at first second; FVC: Forced vital capacity; ml: Mililitres; ppd: Predicted percentage; Tx: Transplant.