Table 1: Pumping test data and VES parameters in study area.

VES

Well Name

Total Thickness (m)

Total Transfers Resistance

Well Log Transmissivity

Estimated Transmissivity

(m2/d)

Well Hydraulic Conductivity

Estimated Hydraulic Conductivity

V2

MGPW2

231.2

4276.7

263.87

238.1942

2.6

1.030252

V8

MGTW2

482.1

14571

1021.72

818.7899

1.39

1.698382

MV7

MT3

109.1

746.24

32.06

39.07344

0.314

0.358143

MV3

MGPW1

419.3

5962.5

389.78

333.2722

1.22

0.79483

MV5

MT1

450

15150

921.72

851.4545

2.01

1.892121